Around 12% of patients carry genetic variants associated with high reactivity to cobalt-chrome or titanium metal alloys 

This reactivity is associated with lower patient-reported outcome scores and a higher risk of developing adverse reaction to metal debris following joint replacement.

Solution

Orthotype® uses next-generation DNA sequencing to identify a patient’s HLA genotype

This genotype is converted into a Genetic Reactivity Score (GRS) for each of the two metal alloys in common use: the CoGR and TiGR scores, for cobalt-chrome and titanium respectively.

The higher the CoGR or TiGR score, the greater the risk of lower PROMs and aseptic revision following joint replacement using that metal alloy.

Orthotype® allows the clinician and patient to select the most appropriate implant alloy for the individual’s genetic profile.

Orthotype® output

The patient’s CoGR and TiGR scores are plotted on a chart alongside the genetic variation seen in an average background population of European descent.

In this example, the patient has a lower CoGR score than TiGR score, which means that their HLA genotype is likely to be more compatible with a cobalt-chrome implant than a titanium implant.

How to order Orthotype®

How does it work?

  1. Order placed with ExplantLab
  2. Sample kit dispatched
  3. Blood drawn through standard venesection
  4. Sample placed in prepaid collection box
  5. Report returned within 10 working days from receipt

To enquire about ordering test kits, please fill in the contact form below.

Frequently Asked Questions

Higher genetic reactivity scores (GRS) are associated with an increased risk of lower patient reported outcomes.

In knee arthroplasty, on average (with adjustment for other factors such as age, BMI and gender), each increase in GRS is associated with a five point reduction in Forgotten Joint Score.

Patients with a high GRS are far more likely to develop metal hypersensitivity (ALVAL) at equivalent levels of metal exposure.

No it does not, it just means there is a higher probability.

For example, if a patient with a high CoGR score is implanted with a CoCr device which releases very little metal debris, the risk of a poor outcome is reduced.

However, it is difficult to predict how a device will perform after implantation.

Higher genetic reactivity scores (GRS) are associated with an increased risk of all of the following conditions, which should be viewed as step-wise increases in severity and risk of long term complications:

GEN-APHID: Genetically associated arthroplasty pain, histologically ill-defined. Pain without a clearly established pathological mechanism. Appears to be a non or slowly progressive condition with the risk of soft tissue and/or bone necrosis relatively low.

ARMD: Adverse reaction to metal debris. Inflammatory response characterised by a heavy infiltration of histiocytes reacting to metallic debris. With ARMD, there is a significant risk of progressive bone damage.

ALVAL: Aseptic lymphocyte dominated vasculitis associated lesion. A subset of ARMD. Histiocytic and lymphocyte infiltration (delayed type hypersensitivity). With ALVAL, there is a significant risk of progressive bone and soft tissue damage.

ARMD (including ALVAL, delayed type metal hypersensitivity which is a type 4 allergy) has well described pathological features; the Orthotype® test was developed through the study of histologically proven cases of ARMD.

In standard medical grade cobalt chrome and titanium implants, nickel makes up only a tiny fraction of the metal alloys (<0.5%).

In other words, in a typical cobalt chrome implant, there is approximately 300 times more cobalt by weight than nickel, and in titanium alloys, this figure reaches over 500.

To our knowledge, histologically proven ARMD in association with nickel allergy (in the absence of exposure to other metals) has not been documented in significant patient numbers. In light of our own research findings and those of the Oxford group, we do not recognise a positive lymphocyte transformation test (LTT) as diagnostic of nickel sensitivity.

Yes – we can work with your pathology lab to get Orthotype® on the Trust system. This process can take time, and in the meantime, ordering test kits directly from ExplantLab is the quickest way to access testing for your patients.

No. A saliva-based test can be mailed out to patients.

With regard to skin patch testing, we do not know. We are currently setting up a study to investigate this with colleagues in the United States.

With regard to LTTs, we have not found good agreement. This may be due to differences in how the tests were developed, and what they are looking for. Orthotype® was developed originally on histopathologically proven cases of ALVAL.

Orthotype® is based on nearly two decades of research into implant wear, metal ions, adverse immune responses and the underlying genetic associations.

This research has been published in high quality orthopaedic and medical journals and has won awards from orthopaedic and immunology professional societies. Please see the Research page for more information.

Orthotype® outputs rely only on a patient’s HLA. It does not take into account other variables which may affect immune responses, such as genetic variants outside of the HLA region or lifestyle factors.